Installation
2.1
General instructions
Do not install the device at places exposed to the bad weather or to the extreme
!
temperatures.
The central unit is protected from the opening, but the installation in a safe place is a
!
greater protection of the device.
For a strong and safe fixing, it needs making sure the wall surface is plane.
!
Fixing the device by the four fishers included in the central unit and no replacing them with
!
others of more small size.
Fixing the central unit at a height that allows an easy access to the frontal panel.
!
The central unit must be connected with an alarm system according to CEI 79-3 Standard
!
or similar.
2.2
Power supply
It 's important to know that the entire system is powered exclusively by the 12V 7,5Ah lead
battery inside of the burglary central unit; the lead battery is constantly in charge by the power
supplier/battery connected to the 230V~ main power supply.
WARNING!
The main power supply 230V~ has to be connected to the power supplier/battery
charger by two 1,5mm² double-isolation wires coming from a sectioning switch(i.e. a
magneto-thermic protection switch) used exclusively for the burglary central unit.
Inside of the central unit positioning orderly the two wires, locking them by wrappers.
Installation
Switch
230V~
50Hz
main power supply