6. Run the compressor for 20 minutes. Make sure the globe valve is open and
there is minimal air pressure build-up in tank.
7. Check all air line fittings and connections/piping for air leaks by applying a
soap solution. Correct if necessary. NOTE: Minor leaks can cause the air
compressor to overwork, resulting in premature breakdown or inadequate
performance.
8. Check for excessive vibration. Readjust or shim air compressor feet, if nec-
essary.
9. After 20 minutes, close the globe valve. The air receiver will fill to "cut-out"
pressure and the motor will stop.

Before Each Start-Up:

1.
Place On/Auto/Off lever to "Off".
2.
Close the globe valve.
3.
Attach hose and accessories. NOTE: A regulator MUST be installed when
using accessories rated at less than 175 PSI.
NOTE: The hose or accessory will require a quick connect plug if the air outlet
is equipped with a quick connect socket.
Risk of Bursting. Too much air pressure causes a hazard-
ous risk of bursting. Check the manufacturer's maximum
pressure rating for air tools and accessories. The regulator outlet pressure
must never exceed.

How to Start:

1.
Turn the On/Auto/Off lever to "On/Auto" and allow tank pressure to build.
Motor will stop when tank pressure reaches "cut-out" pressure.
2.
When the tank pressure reaches "cut-out" pressure open the globe valve.
IMPORTANT: When using regulator and other accessories refer to the manufac-
turers instructions.
The compressor is ready for use.