TECHNICAL SPECIFICATIONS
Supply voltage:
12 V - 24 V AC +/-10% ; 12 V - 30 V DC +/-10%
Power consumption:
< 2.5 W
Mounting height:
2 m to 3.5 m
Temperature range:
-25°C to +55°C; 0-95% relative humidity, non condensing
Degree of protection:
IP54
Noise:
< 70 dB
Expected lifetime:
20 years
Applicable directives:
MD 2006/42/EC; EMC 2004/108/EC; ROHS 2 2011/65/EU
Detection mode:
Technology:
Output:
Test input:
Norm conformity:
SAFETY INSTRUCTIONS
The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system
in compliance with applicable national and international regulations and standards on door safety and if applicable, the machinery directive 2006/42/EC.
Only trained and qualified personnel may install and setup the sensor. The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel. Avoid touching any electronic and optical components.
Came S.p.A.- Via Martiri Della Liberta 15 - IT-31030 DOSSON DI CASIER (TV)
TEL (+39) 0422 4940 - FAX (+39) 0422 4941 - info@came.com - www.came.com
Came S.p.A. hereby declares that MR8701 is in conformity with the basic requirements and the other relevant provisions of the directives 1999/5/EC, 2006/95/EC and
2006/42/CE.
Only for EC countries: According to the European Guideline 2012/19/EC for Waste Electrical and Electronic Equipment (WEEE)
Original upon request.
-
-
buy
to
sell product
(local regulations may have an impact on the acceptable mounting height)
Presence
Typical response time: < 200 ms (max. 500 ms)
Active infrared with background analysis
Spot: 5 cm x 5 cm (typ)
Number of spots: max. 24 per curtain
Number of curtains: 2
Solid-state-relay (potential and polarity free)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
Holdtime: 0.3 to 1 s
Sensitivity: Low: < 1 V; High: > 10 V (max. 30 V)
Response time on test request: typical: < 5 ms
EN 12978
EN ISO 13849-1:2008 PL «c» CAT. 2
(under the condition that the door control system monitors the sensor at least once per door cycle)
IEC 61496-1:2012 ESPE Type 2
EN 16005:2012 Chapter 4.6.8;
DIN 18650-1:2010 Chapter 5.7.4
BS 7036-1:1996 Chapter 8.1
Specifications are subject to changes without prior notice.
All values measured in specific conditions.
(to be operated from SELV compatible power supplies only)