Mediclinics SC0004 Manual De Instalación Y Utilizacion página 12

Tabla de contenido

Publicidad

5. Reinstall the dryer cover:
- Fix the cover in place from the front.
- The base clips should enter
their respective housings in the
cover.
- Move the cover upwards.
- Insert and screw in place the
two lower screws using the
special key.
6. Check for correct positioning of the air
output handle in its holder.
7. Check for correct operation of the section:
- The handle in its holder (hung-up): OFF
- The handle is picked up (not hung-up): ON
Alternatively, there are models of this dryer that incorporate power
cable and plug, in which case sections 2 and 4 of the described
procedure are no longer necessary and the unit has only to be
plugged into a wall socket.
It is suggested that the appliance be installed at a certain height
from the floor and not less than d = 20 cm from the nearest wall.
Terminal strip and 22-mm diameter entrance hole
Minimum dryer-shelf and dryer-wall distances
-12-
Terminal srip
22-mm diameter
entrance hole

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sc1004

Tabla de contenido