INSTAllATION INST UcTIONS
cONNEcTiNG
ELEcTRic DRYERS {cont.)
USA ONLY
WARN|NG:
• Connect
the power
cord
to the terminal
block.
Each colored
wire should
be connected
to same
color
screw.
Wire color
indicated
on manual
is connected
to the same
color
screw
in block.
Failure
to follow
these
instructions
may result
in a short
or overload.
• Grounding
through
the neutral
conductor
is prohibited
for: (1) new branch-circuit
installations,
(2) mobile
homes,
(3) recreational
vehicles,
and (4) areas
where
local
codes
prohibit
grounding
through
the neutral
conductor.
©
Four-wire
Connection
for Electric
Dryers:
Power
Cord
• A 4-wire connection
is required for all mobile
and manufactured home installations, as well
as all new construction
after January 1, 1996.
A UL-listed strain relief is required.
= Use a 30-arnp, 240V, UL-listed
power cord
with #10 AWG=minimum copper conductor
and closed loop or forked terminals with
upturned ends.
Terminal
Block
UL-Listed
Relief
"_
UL-Listed
4-Wire
Power Cord
Remove the terminal block access cover
on the upper back of the dryer. Install a
UL-listed strain relief into the power cord
through-hole;
then thread a UL-listed, 30A,
240V, 4-wire, #10 AWG-rninirnurn
copper
conductor
power cord through the
strain relief.
Hot
Neutral _Hot
(Black)--
(White)
(Red)
Ground Screw _1
Ground Wire
,_
Transfer the dryer's ground wire from behind
the green ground screw to the center screw
of the terminal block. Attach the two hot
leads of the power cord to the outer terminal
block screws. Attach the white neutral wire
to the center terminal block screw. Attach the
power cord ground wire to the green ground
screw. TIGHTEN ALL SCREWS SECURELY.
Reinstall the terminal block access cover.
19