Descargar Imprimir esta página

Specifications; Warranty And Registration - NSS CXC 200 Instrucciones Para El Usuario

Ocultar thumbs Ver también para CXC 200:

Publicidad

Idiomas disponibles

Idiomas disponibles

DAILY OR AFTER EACH USE
Clean vacuum shut-off valve and strainer (Fig. 7).
Empty recovery tank, then remove the recovery tank lid.
Grasp the PVC elbow and gently pull towards the front of
the tank. Rinse the assembly clean and make sure float
ball moves freely inside the screen. Align the slot and
the screw and reinstall the PVC elbow securely.
Clean the solution inlet filter. Loosen the tank
attachment screw (Fig. 1) and open the unit. Remove the
filter cover and strainer screen (Fig. 5). Rinse the strainer
screen clean in warm water. Replace the strainer and
retighten the filter cover.
Note: The CXC 1200 is equipped with two filters: a
solution inlet filter and a recovery tank outlet filter. Both
filters should be cleaned after each use.
MONTHLY
Clean the internal plumbing by rinsing with clear water
at the end of each job. About once a month, rinse the
machine with a commercial flushing compound to break-
up any mineral or chemical accumulation that may have
formed from the use of hard water or chemicals
AS NEEDED
Lubricate the solution line quick-connect couplings
(Fig. 1) with a small amount of rust-inhibiting oil such as
WD-40.
To maintain a professional appearance, wipe the
interior and exterior surfaces with a damp cloth. For deep
cleaning and a lasting, protective shine., use an auto
interior product, like Armor-All Protectant.
WARRANTY
Warranty information is available from your dealer or at
www.nss.com.
Manual 4092471 (Rev 022912) 
Warranty registration
Visit
www.nss.com
Registration allows us to better assist you with using,
maintaining or servicing your equipment, as well as to
contact you in case we have important safety information
concerning your NSS product. If you determine service is
required, have your equipment model, serial number, and
original proof of purchase available, and call your
distributor for assistance with obtaining a return material
authorization (RMA).

SPECIFICATIONS

ALL MODELS
Vacuum
Two, dual-stage. Installed in series.
motors
Solution tank: 10 gal. ( 37.9 l)
Capacity
Recovery tank: 10 gal. ( 37.9 l)
Rotomolded polyethylene housing and handle;
Construction
semi-pneumatic wheels.
Dimensions
39.5 × 32 × 19.75 in.
(H × L × W)
100.3 × 81.2 × 50.2 cm
Model
Features
CXC 200
200 PSI
CXH 200
200 PSI, 2000W heater
CXH 500
500 PSI adjustable. 2000W heater.
Pressure gauge.
CXC 1200
1200 PSI, adjustable. Pressure
gauge. Auto-fill. Automatic pump-out.
CONTACT
NSS Enterprises, Inc.
Corporate Headquarters
3115 Frenchmens Rd.
Toledo, OH 43607
419 531 2121
www.nss.com
5
to register your purchase.
Dry weight
75 lbs.
34 kg
83 lbs.
38 kg
98 lbs.
45 kg
124 lbs.
56 kg

Publicidad

loading

Productos relacionados para NSS CXC 200

Este manual también es adecuado para:

Cxh 200Cxh 500Cxc 1200