LEGEND:
F1: 5A fuse connected to the vehicle battery to power the side marker lights
F2: 20A fuse connected to the vehicle battery to power the fridge
F3: 15A fuse connected directly to the service battery to power the step
F4: 30A fuse connected directly to the service battery to power the Webasto / Auxiliary
F5: 15A fuse connected to lights master switch to power the group of lights_1
F6: 15A fuse connected to lights master switch to power the group of lights_2
F7: 10A fuse connected directly to the service battery to turn on the fridge and heater and to the pump
switch to power the water pump
F8: 10A fuse connected directly to the service battery to the courtesy light and external light switch
F9: 15A fuse connected to the AUX switch
Attention:
When replacing faulty fuses, observe the correct amperage.
OPERATION:
Power activated from control panel:
The outputs for internal lights (lights_1 and lights_2), external light, pump and aux are activated
directly by the relevant keys on the control panel.
Services activated by D+:
The coupler relay and fridge relay are enabled immediately in one of these two conditions:
+Alternator
G
JP6 pin1
+12V
The coupler relay recharges the service battery with the alternator when the engine is running.
The fridge relay powers the three-purpose fridge at 12V when the engine is running.
The external light goes out automatically when the engine is running
Side marker signal:
The side-marker output can be activated with a negative control (negative) on the JP13 block, pin 4, or
with a positive control (+12V) on the JP13 block, pin 1.
Car battery recharge:
The coupler relay recharges the starting battery with the charger battery when
mains supply
.
The relay is excited when the service battery exceeds 13.5V and
230V mains supply
SHUNT NE185_11S
or
is turned off or the service battery voltage is below 12.8V.
+key
KEY-ON
JP13 pin 3
+12V