a
Quick start guide
Smoke alarm
For more information see
the extended manual online:
ned.is/dtctsl50wt
Intended use
This product is intended for smoke detection. Other
uses or changes to the product constitute improper
use and carry serious risk of accidents. This product
is for indoor use only. This product is not intended
for commercial use.
The product must not be mounted in damp rooms,
near doors, windows, ventilators or radiators.
Any modification of the product may have
consequences for safety, warranty and proper
functioning.
Main parts (image A)
1
Smoke alarm
2
Indicator LED
3
"Test / Hush" button
4
Magnet
Preparation (image B - D)
Install the product on the wall or ceiling.
The product must be installed:
•
In each room.
•
On each floor.
•
In the hallway.
•
In the staircase.
•
In the storage room.
•
In spaces with electric equipment.
-
Do not install in the tip of a sloping ceiling as
smoke-free air can collect in these areas.
•
Install the product on the ceiling where 1 m from
the highest point of the ceiling.
•
Install the product at least 61 cm from the corner
of the wall.
•
Install the product at least 50 cm from
fluorescent light sources.
Installation of the product (image E)
5
1. Turn A
counterclockwise to remove it from
1
A
.
DTCTSL50WT
5
Mounting bracket
6
Screw (3 x 25 mm)
7
Plug (6 x 28 mm)
4
2. Remove A
from A
product.
5
3. Place A
in the desired location.
5
4. Use A
to mark the drill locations with a pencil.
5. Drill two Ø 6 mm holes.
6. Insert the plugs.
7. Fasten the mounting bracket with A
1
8. Turn A
clockwise to attach it to A
Testing the product
The product must be tested to ensure proper
operation.
1. Press and hold A
continuous "beep" and A
3
2. Release A
. The "beep" stops and A
blinking.
The product is now in hush mode.
3. Repeat the above steps to exit the hush mode
and finish the test.
Hush mode
In hush mode, the product does not detect smoke
for 9 minutes.
The hush mode must be activated manually.
3
1. Press A
shortly to activate hush mode. The
LED blinks every 10 seconds.
After 9 minutes, the product goes back into standby
mode.
Tip: To leave the hush mode early, hold down A
until the product emits a "beep".
4
Note: In hush mode, the alarm is still triggered
when the smoke concentration in the ambience
is over 4 times the minimum alarming value.
Status of smoke alarm
LED light
Standby mode Blinks every
344 s
Hush mode
Blinks every
10 s
Test
Blinks
continuously
Low-battery
No LED
condition
function
Malfunction
No LED
or end-of-life
function
4
1
to switch on the
6
.
5
.
3
until the product emits a
2
starts blinking.
2
Sound alarm
Off
Off
Continuous
"beep"
A "beep" every
43 s
A series of
"beeps" every
43 s
stops
3