17
Quick Start Guide
Specifi cations
Processing
A/D-D/A conversion
(Cirrus Logic A/D CS5368, D/A CS4385)
Networked I/O latency
(stagebox in > console processing* > stagebox out)
Connectors
Programmable mic preamps, designed by MIDAS, balanced XLR
Line outputs, balanced XLR
AES/EBU outputs (AES3 XLR)
AES50 ports, SuperMAC networking, NEUTRIK etherCON
ULTRANET output, RJ45 (no power supplied)
MIDI inputs / outputs
ADAT outputs, Toslink
USB port for system updates, type B
Mic Input Characteristics
Preamp design
Input impedance XLR, unbal. / bal.
Non clip maximum input level, XLR
THD + noise, 20 dB gain, 0 dBu out
Phantom power, switchable per input
Equivalent input noise level, XLR (input shorted)
CMRR, XLR, @ 20 dB gain (typical)
Input/Output Characteristics
Frequency range, @ 48 kHz sample rate, 0 dB to -1 dB
Dynamic range, analog mic in to analog out (typical)
A/D dynamic range, mic preamp and converter (typical)
D/A dynamic range, converter and output
Cross talk rejection @ 1 kHz, adjacent channels
Output Characteristics
Output level, XLR, nom./max.
Output impedance, XLR, unbal. / bal.
Residual noise level, XLR
Digital In/Out
AES50 SuperMAC networking @ 48 or 44.1 kHz, 24-bit PCM
AES50 SuperMAC cable length, CAT5e shielded**
ULTRANET networking @ 48 or 44.1 kHz, 22-bit PCM
ULTRANET cable length, CAT5 shielded
ADAT output @ 48 or 44.1 kHz, 24-bit PCM
Toslink optical, cable length
AES/EBU output @ 48 or 44.1 kHz, 24-bit PCM
XLR, 110 Ω balanced, cable length
Power
Switch-mode autorange power supply
Power consumption
Physical
Standard operating temperature range
Dimensions
Weight
*includes all channel and bus processing, excluding insert eff ects
**KLARK TEKNIK NCAT5E-50M recommended
NOTE: Please verify that your specifi c AES50 connections provide stable operation prior to using the products in a live performance or recording situation. The maximum distance for
AES50 CAT5 connections is 100 m / 330 ft. Please consider using shorter connections where possible for gaining safety margin. Combining 2 or more cables with extension connectors
can reduce the reliability and maximum distance between AES50 products. Unshielded (UTP) cable may work well for many applications, but entails an additional risk for ESD issues.
We guarantee, that all our products will perform as specifi ed with 50 m of KLARK TEKNIK NCAT5E-50M, and we recommend using cable of similar quality, only. KLARK TEKNIK also
off ers the very cost-eff ective DN9610 AES50 Repeater or DN9620 AES50 Extender for situations where extremely long cable runs are required.
24-bit @ 44.1 / 48 kHz,
114 dB dynamic range
1.1 ms
32
16
2
2
1
1/1
2
1
MIDAS
5 kΩ / 10 kΩ
+23 dBu
< 0.008% (< 0.006% A-weighted)
48 V
-128 dBu
> 70 dB
10 Hz - 22 kHz
104 dB
106 dB
106 dB
100 dB
+4 dBu / +21 dBu
75 Ω / 75 Ω
-83 dBu (-85 dBu, A-weighted)
2 x 48 channels, bidirectional
up to
m
100
1 x 16 channels, unidirectional
up to 75 m
2 x 8 channels, unidirectional
5 m, typical
2 x 2 channels, unidirectional
5 m, typical
100-240 V (50/60 Hz)
55 W
5°C to 40°C (41°F to 104°F)
483 x 242 x 138 mm (19 x 9.5 x 5.4")
5.6 kg (12.4 lbs)