Drum lifter with cable winch
Always ensure the winch is in good operating condition. Machinery which is not maintained can lead to
incorrect operation and accidents.
The lifting cable should be checked along its entire length, even where parts are hidden.
If the cable is damaged, the drum lifter should be withdrawn from service and the cable replaced.

9. Types FH-EX (Ex version equipment)

9.1 Application and intended use

in addition to section 3. For the "Application and intended use" of Ex version equipment, the following notes
apply:
The product must only be used in accordance with the instructions and the product identification. The
identification is located on the product identification plate.

9.2 Additional Instructions

In addition to the previous section, for Ex version equipment the following notes apply:
The drum lifter must only be unpacked in a non-Ex area.
Handling flammable liquids, explosion protection measures
During the handling, storage and dispensing of substances which can create an explosive atmosphere,
the requirements of ATEX Directive 94/9/EC and 1999/92/EC must be observed in addition to the 11th
Machinery Safety Law (GSGV) and the Industrial Safety Regulations (BetrSichV). Depending on the Ex-
zone, suitable protective measures are to be taken. Emphasis must be laid on preventing a build-up of
explosive atmosphere by altering the concentration (eg ensuring sufficient ventilation), operating
conditions, and constructive organisation (eg using suitable and approved containers, suitable storage
facilities).
It must be ensured that sources of ignition caused by electrostatic charges are avoided by using electrical
equipotential bonding. Mechanically produced sparks must be avoided by using suitable tooling, transport
and loading equipment for example. Thermal ignition sources must be avoided by using suitable
techniques, prevention of friction, lightening protection, and the prohibition of open flames, open lights
and smoking.
Organisational measures such as the identification of areas, implementation of warning signs and access
prevention for unauthorised personnel are required.
Equipment must be maintained in good condition, operated correctly and regularly inspected. Any necessary
repairs must be carried out immediately. Repairs which may affect the explosion protection of a piece of
equipment must only be carried out by the manufacturer.
Check that the coating on the load bearing parts of the drum lifter is in perfect condition. If corrosion is
present, the drum lifter may not be used.
Storage requirements as per TRGS 510 must be observed.
Electrical conductivity can be changed by the depositing of hindering substances and also by chemical and
mechanical influences in such a way that the permitted values laid down in the standards are exceeded. In
particular, dust, dirt and paint, acids and alkalis, overloads and impact loads can lead to the
discharge/conduction of electrical/electrostatic energy to the floor being reduced or completely interrupted.
212876_BA_INT_004 Fasslifter Servo mit Fassklammer SK
214474, 214475, 214476, 214477
214478, 214479, 214480, 214481
Seite 13 von 27 Seiten