Description Of The Rollixo Receiver; Area Of Application; Description Of The Receiver - SOMFY Home Motion ROLLIXO RTS Manual De Instalación

Ocultar thumbs Ver también para Home Motion ROLLIXO RTS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Rollixo RTS
1.8 risk prevention
risk prevention - roller garage door motorisation for
residential use
> risk zones: measures to be taken to eliminate risks.
Zone 3
Zone 4
risK
ZONE 1
Risk
of
crushing
between the ground
and the lower edge of
the door during closing
ZONE 2*
Risk
of
crushing
between the casing
and door
ZONE 3*
Risk of cutting or
trapping between the
door slats in gaps of
between 8 mm and 25
mm
ZONE 4*
Risk
of
crushing
between the runners
and door
* For zones 2, 3 and 4, no protection is required if the door
has continuous control or if the danger zone is more than
2.5 m above ground or any other permanent access level.
Copyright © 2014 Somfy SAS. All rights reserved.
WarninG
Zone 2
Zone 1
soLution
Obstacle
detection
using
safety edge solution (confirm
detection
using
a
force
measurement - see Force
measurement paragraph)
For operation with automatic
closing, install photoelectric
cells (see installation manual)
Eliminate any gap ≥ 8 mm or
≤ 25 mm between the casing
and door
Eliminate all sticking points
and all sharp edges from the
surface of the door
Eliminate any gap ≥ 8 mm or
≤ 25 mm
Eliminate any sharp edges
from the runners
Eliminate any gap ≥ 8 mm
between the runners and the
door
> force measurement
Take the mid-height measurement of
1
the garage door by positioning the
measuring tool perpendicular to the
1400N
panel which is closing.
F
The standard stipulates:
d
- dynamic force ≤ 400 N
- dynamic time ≤ 750 ms
Other specifications set out in this
400N
standard are validated by Somfy
during initial type testing.
150N
25N
T
d
2 - DesCriPtion of the roLLiXo
reCeiver

2.1 area of application

The ROLLIXO receiver, linked to a Somfy RDO CSI motor and a Somfy safety
edge solution, is designed to drive a vertically opening roller garage door for
residential use with the following external dimensions:
- Height = 4 m maximum
- Width = 6 m maximum
number of cycles per hour: 5 cycles/hour spread evenly throughout the hour

2.2 Description of the receiver

10
14
12
13
9
8
7
11
no.
Description
1
Integrated lighting bulb
2
Receiver cover
3
Receiver cover bolt
4
External programming interface
5
Internal programming interface
6
433.42 MHz aerial
7
Plug-in terminals
8
Cable clamp
9
Cable clamp bolt
10
Alarm bolt
11
Fall protection shunt
12
Safety fuse for motor and integrated lighting
13
Spare fuse
14
E14 - 15W max - 230V bulb
1
4
5
2
3
6
3

Publicidad

Tabla de contenido
loading