After a successful zero point comparison and leaving the setting menu, the SmartBox
display "0L". After this, the mechanical level gauge FSA-W 4-20 mA can be installed in the
tank (if the start-up was completed with a filled tank).
18.Language+
name
4 / 8
Input function
Press [ENTER] to return to display mode.
Select measuring range:
For the appropriate conversion to the measurement
range of the FSA-W 4-20 mA 0-250 cm.
Selection of the operating medium or the input of the
density:
For the appropriate conversion to the measurement
range of the FSA-W 4-20 mA 0-250 cm.
By selecting "Input Density", "Tank" will be shown in
the display (instead of Medium), this can be
changed under menu step 18.
Select Tank shape with [Enter].
Adjust the tank volume with [+] / [-] (100%). The default
setting is 0L. The value must be set.
For the appropriate conversion to the measurement
range of the FSA-W 4-20 mA 0-250 cm.
Depending on the equipment version (from V6.xx)
skip with [+].
Depending on the equipment type and version
skip with [+].
Depending on the equipment type and version
skip with [+].
Skip with [+].
Adjustment of: Sensor zero point electrical
requirements:
• Level gauge FSA-W 4-20 mA is at the 0-point (arrow
on 0 cm) and/or is pulled out at the height of the
ground level of the tank,
• the zero point comparison "Set Null" was carried out
in this position,
manual Part no.15 276 51
Selection of the language and input of the text for the
tank designation / medium.
Changing the tank designation:
Change the lettering with [+]/ [-]/ [Enter].
Konfiguration von SmartBox
refer to the assembly and operating
-
.
®
1 +2+3+4
Input value
250mbar
999kg/m³
_________
_________L
250.0cm
Offset
calibr.
®
must
Language:
Text:
Artikel-Nr. 15 811 50