Descargar Imprimir esta página

Craftsman 919.165381 Manual Del Usuario página 13

Ocultar thumbs Ver también para 919.165381:

Publicidad

Idiomas disponibles

Idiomas disponibles

Air Compressor
Pump (not shown}:
Compresses air into the air tank.
Working air is not available until the
compressor
has raised the air tank
pressure above that required at the
air outlet.
Oheek Valve: When the air
compressor
is operating, the check
valve is "open", allowing compressed
air to enter the air tank.
When the
air compressor
reaches "cut-out"
pressure, the check valve "closes",
allowing air pressure to remain inside
the air tank.
Check Valve
How to Use Your Unit
Bow
to Stop:
1.
Set the On/Auto/Off
lever to
"OFF".
Before First Start Up
damage
may resumt if the following
breakqn
instructions
are not
emoseByfolmowed°
This procedure is required before the
air compressor is put into service and
when the check valve or a complete
compressor
pump has been replaced.
1.
Make sure the On/Auto/Off
lever
is in the "OFF" position.
2.
Plug the power cord into the
correct branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph in the
Insta!Iation section of this
manual.)
3.
Open the drain valve (counter-
clockwise) fully to permit air to
escape and prevent air pressure
build up in the air tank during the
break-in period.
4.
Move the On/Auto/Off
lever
to "ON/AUTO"
position. The
compressor will start.
5.
Run the compressor
for 15
minutes. Make sure the drain
valve is open and there is
minimal air pressure build-up in
tank.
6.
After 15 minutes, close the drain
valve by turning c!ockwise. The
air receiver wilI fill to "cut-out"
pressure and the motor will
stop.
The compressor is now ready for use.
13-ENG
A08596

Publicidad

loading