Maintenance
Inspect and clean all components and replace if necessary.
Disconnect voltage supply.
Shut off hot and cold water supply.
Disconnect all plug-in connectors, see Fig. [4].
I. Change digital controller batteries, see Fig. [7].
Batteries which are almost discharged are indicated by
shortened signals of the illuminated ring after pressing
a button. Batteries must be changed at the latest when
signals are no longer detected.
Lever off base and change all batteries, see technical product
information for the digital controller. Insert batteries with
correct polarity.
Assemble in reverse order.
II. Change functional unit battery, see Fig. [8].
A battery which is almost discharged is indicated by two brief
water pulses.
The battery must be replaced 10 years after commissioning
the faucet, at the latest.
Insert battery with correct polarity.
Assemble in reverse order.
III. Flow regulator (13 220), see fold-out page I.
Assemble in reverse order.
Fault
Cause
Water not flowing
• Water supply interrupted
• Plug-in connector without contact or no
power supply
Flow rate too low
• Faucet mousseur dirty or defective
• Functional unit not adapted to local
conditions
Water too cold/hot
• Functional unit not adapted to local
conditions
No function
• No voltage supply to functional unit
• Controller not ready
Controller flashes
• Digital controller out of range
white
English
Service
In the event of problems with installation, please interrupt
the voltage supply and consult a specialist installer or
the GROHE Service Hotline via email under
TechnicalSupport-HQ@grohe.com.
Replacement parts
See fold-out page I (* = special accessories).
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.
Disposal instructions
This category of device does not belong in the
domestic waste, but must be disposed of
separately in accordance with the relevant local
national regulations.
Dispose of batteries in accordance with national
regulations.
Remedy
- Open shut-off valves, isolating valves
- Attach plug-in connectors and connect voltage
supply
- Replace flow regulator, see section Maintenance
Calibrate functional unit, see section
Selection menu
- Calibrate functional unit, see section
Selection menu
- Connect voltage supply via power supply unit
- Insert batteries
- Reduce distance or use transceiver special
accessory (36 356)