Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Please read all instructions before installing
Universal Application Wall Switch
with Manual ON/OFF
SPECIFICATIONS
Voltage ............................................................... 120VAC, 60Hz
Load (Single Pole Circuit)
Incandescent or fl uorescent ............................ 0-600 Watts
Fan motor .................................................................. 1/6 hp
Time Delay Adjustment ....................15 seconds to 30 minutes
Light Level Adjustment ....................................... 10 fc to 150 fc
Environment ..................................Residential Indoor use only
Operating Temperature ............... 32° to 131°F (0° to 55°C)
Humidity ...................................... 95% RH, non-condensing
Tools Needed
Insulated Screwdriver
Wire Strippers
DESCRIPTION AND OPERATION
The RS-250 Universal Application Wall Switch Vacancy Sensor is designed to
replace a standard light or fan switch. It is ideal for living and dining rooms, family
rooms, bedrooms, bathrooms and any other indoor area in a residential space
where occupancy sensor-based manual ON/OFF controls are desirable.
Like a standard switch, you press the ON/OFF button to turn the light or fan
(controlled load) ON and OFF. Unlike a standard switch, the RS-250 automatically
turns OFF the controlled load after the coverage area has been vacant for a period
of time (Time Delay). If motion is detected within 30 seconds after it automatically
turns OFF, the RS-250 automatically turns the load back ON.
While the sensor is factory preset as a Vacancy Sensor with manual ON operation,
it can be adjusted to work as an Occupancy Sensor that turns the controlled load
ON automatically upon detection of occupancy in the area.
Lighted Switch
To help you locate the RS-250 in a dark room, the amber LED illuminates the
ON/OFF button while the controlled load is OFF. When the controlled load is ON,
the LED is OFF.
Operating Modes
There are two operating modes to select from during set up:
MODE 1
Vacancy sensor (Manual-ON/OFF, Auto-OFF): The user must press
the ON/OFF button to turn the load ON. The RS-250 keeps the load ON until no
motion is detected for the selected time delay period (adjustable from 15 seconds
to 30 minutes). There is a 30 second reset delay. If motion is detected during this
time, the sensor turns the load back on automatically. After the reset delay time
has elapsed, the ON/OFF button must be pressed to turn ON the load.
MODE 2
Occupancy sensor (Auto-ON/OFF with manual control and reset
to auto after 5 minutes of vacancy): The load turns ON and OFF automatically
based on occupancy detection. The RS-250 keeps the load ON until no motion is
detected for the selected time delay period. If the load is turned OFF manually,
automatic-ON is re-enabled when no motion is detected for 5 minutes. This
prevents the load from being turned ON after it was deliberately turned OFF.
Call 888.817.0571 for Technical Support
RS-250
Vacancy Sensor
Lens
Lighted Switch
ON/OFF button
Santa Clara, CA 95050

Publicidad

Tabla de contenido
loading

Resumen de contenidos para LEGRAND Watt Stopper RS-250

  • Página 1 Please read all instructions before installing RS-250 Universal Application Wall Switch Vacancy Sensor with Manual ON/OFF Lens Lighted Switch ON/OFF button SPECIFICATIONS Voltage ............... 120VAC, 60Hz Load (Single Pole Circuit) Incandescent or fl uorescent ......0-600 Watts Fan motor ..............1/6 hp Time Delay Adjustment ....15 seconds to 30 minutes Light Level Adjustment ........
  • Página 2: Time Delay

    Time Delay The time delay can be selected by the user during set up. It can be adjusted from 15 seconds up to 30 minutes. For additional information on how to adjust it, please read the SENSOR ADJUSTMENT & PROGRAMMING section of this installation manual.
  • Página 3 4. Wire the sensor. Twist the existing wires together with the wire leads on the RS-250 sensor as Red – > LOAD (power Black – > HOT (power to lamp or fan) indicated below. Cap them from circuit box) securely using the wire nuts provided (See Fig 4).
  • Página 4: Test Mode

    Adjusting the Light Level This feature is factory set at maximum, so that even the brightest light will not prevent the sensor from turning the load ON when it detects occupancy. If this feature is not needed, leave the light level at maximum, fully clockwise. 1.
  • Página 5: Warranty Information

    WARRANTY INFORMATION Watt Stopper/Legrand warranties its products to be free of defects in materials and workmanship for a period of fi ve (5) years. There are no obligations or liabilities on the part of Watt Stopper/Legrand for consequential damages arising out of, or in connection with, the use or performance of this product or other indirect damages with respect to loss of property, revenue or profi...
  • Página 6: Especificaciones

    Por favor leer todas las instrucciones antes de realizar la instalación RS-250 Sensor de Desocupación de pared confi gurable con control manual de ENCENDIDO/ APAGADO Lente Botón iluminado de ENCENDIDO/APAGADO ESPECIFICACIONES Voltaje ................120VAC, 60Hz Carga (Circuito unipolar) Lámparas incandescentes o fl uorescentes ......0-600 Watts Un motor ...................
  • Página 7: Instalacion Y Cableado

    MODO 2 Sensor de Ocupación (ENCENDIDO/APAGADO automático con control manual y retorno a ENCENDIDO AUTOMATICO después de 5 minutos de desocupación): la carga se enciende y se apaga automáticamente por detección de ocupación. El RS-250 mantiene la carga encendida hasta que deje de detectar movimiento por un periodo de tiempo igual al defi...
  • Página 8: Configuracion & Programacion Del Sensor

    4. Conecte el sensor. Strip Gage Tuerza conjuntamente los cables existentes en la caja de conexiones con los cables del sensor 1/2" RS-250 utilizando los conectores (“wire nuts”) 12.7 mm provistos de acuerdo al diagrama Fig. 4. Fig. 3: Pelado apropiado del •...
  • Página 9: Modo De Prueba

    • Un patrón de dos parpadeos consecutivos, repetido 3 veces, indicará Modo 2 (Operación como Sensor de Ocupación), ENCENDIDO/APAGADO automático con control manual y retorno a ENCENDIDO Automático después de 5 minutos de desocupación. • Para cambiar el modo de operación presione el Botón de Selección de Modos. El LED repetirá...
  • Página 10: Informacion Sobre La Garantia De Producto

    (5) años. No existen obligaciones o responsabilidades por parte de Watt Stopper / Legrand por daños ocasionados por o en conexión con el uso o desempeño de este producto u otros daños indirectos en materia de pérdida de propiedad, ventas o ganancias, o...

Tabla de contenido