6. Cancelling user codes remotely
• Type into the keypad the sequence:
*
"#
'code to cancel'
• The keypad will sound a two-second long
beep with the green and red leds lit.
The code has been cancelled
• Move a master tag close to the transponder reader
and hold it there until the reader sounds 5 beeps.
3 sec
3 sec
3 sec
3 sec
CHA
CHB
1 bip
1 bip
2 bip
2 bip
• Once you have chosen the 'DEL' function
remove the master tag from the reader.
• Within 10 seconds bring the tag to be
cancelled near to the reader.
• The reader will sound a beep to confirm.
7. Activating the user code
• Type the user code into the keypad and
*
press "
".
• The keypad will sound a two-second long
beep with the green led lit.
The code has been accepted!
*
#".
3 sec
3 sec
3 sec
3 sec
3 sec
3 sec
CHC
CHD
3 bip
3 bip
4 bip
4 bip
• Press A-B-C or D in the right hand
column of the keypad (e.g. "C")
Activation successful!
• Move a tag containing the channel you
wish to activate near to the transponder
reader.
Activation successful!
8. Setting the impulsive relay mode
• Switch off the power to the interface.
DEL
5 bip
5 bip
• Set the dips according to the table.
Dip #1 Standard Relay 1
Dip #2 Standard Relay 2
Dip #3 Standard Relay 3
Dip #4 Standard Relay 4
• Press and hold down the button P1.
• Power up the interface.
• The interface will sound a lengthy 'beep'.
The parameters have been set
29
Impulsive mode
OFF
ON
Automatic Relay 1
Automatic Relay 2
Automatic Relay 3
Automatic Relay 4