PROBLEMS, CAUSES, REMEDIES
UNICHARGE 4.12 et UNICHARGE 8.12
Error message
The WARNING indicator lights and the
charger beeps
The WARNING indicator lights and the
charger beeps
The load has stopped in the REPAIR
SB (2) or EQUALIZATION (5) stage
and the WARNING indicator lights up
Charging stopped in the CHARGE
DIAG step and the WARNING
indicator lights up
20/36
Causes
Reverse polarity battery
Problem of battery
connection (cables, lugs
...)
Battery voltage selection
error (Unixarge 4.12 only)
Battery voltage too low.
Overvoltage battery (>
15V for a 12V battery,>
7.5V for a 6V battery)
The battery is too
sulphated
Battery does not hold
charge
Battery does not hold
charge
www.uniteck.fr
Solution
Check the connections.
Check that the voltage selected
matches the voltage of your
battery.
Check that the voltage selected
matches the voltage of your
battery.
Check that the selected voltage
matches the voltage of your
battery. If the battery voltage is
less than 3.5V for a 6V and 5V
battery for a 12V battery, the
charge can not start. Select the
Manual Charge mode to force
the load. (See section MANUAL
CHARGE)
Check the health of your
battery. Replace if necessary.
Check the health of your
battery. Replace if necessary.
Check the health of your
battery. Use the RECOND mode
(see RECOND part, Unicharge
8.12 only).
Check the health of your
battery. Replace if necessary.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Unicharge 1,5.12Unicharge 4.12Unicharge 8.12