Operation
With sufficient pressure, operation of the Watts OneFlow
System is completely automatic. Dependable operation involves
only periodic filter changes and service documentation.
Maintenance
Routine maintenance of your OneFlow
filter cartridge changes and/or replacement of sump O-rings.
If the system sizing recommendations have been followed,
the OneFlow
Cartridge should last two years.
®
Filter Change Frequency
The filters should be changed in response to the following conditions.
OFTWH-C-RM • 24 months since installation or last filter change.
3.
2.
System involves periodic
®
6.
8.
4.
®
Replacement Filter Cartridges
OneFlow
systems can only be used with OneFlow
®
cartridges. Use of replacement cartridges other than those
specified will void warranties, certifications and may compromise
equipment protection, water quality and equipment life.
7.
Filter Cartridge Replacement Procedure
1. IMPORTANT: All other equipment connected to the
OneFlow
®
water supply from filters.
2. Turn OFF water to OneFlow
Inlet Ball Valve.
3. Press the red button to release pressure.
4. Remove housing – use filter wrench if necessary.
5. Remove filter from housing. Clean inside of housing with
warm water. If desired, disinfect housing by adding a
teaspoon of household bleach to housing, fill with water, let
stand for 5 minutes, and then discard.
6. Insert new cartridge into filter housing. Match cartridge
model number to model number on bracket.
7. Check O-ring for damage and replace if damaged or
distorted. Make certain the O-ring is properly positioned and
reinstall filter housing (hand tighten only).
8. Slightly open the inlet ball valve; push the red pressure
relief button to release trapped air until a small amount of
water comes out – release the red button and fully open
the ball valve.
9. Open the flush valve downline from the filter housing (if
equipped) and flush the new cartridge to drain or bucket
for two (2) minutes or until water runs clear. If no flush valve
is present, disconnect line from equipment to flush to drain.
10. VERY IMPORTANT: With water supply inlet valve OPEN and
water flow confirmed, turn on connected equipment. Failure
to supply water to equipment may cause serious damage.
11. Record filter change on the service log.
4
system must be turned off prior to shutting off
system by closing
®
filter
®