Operational Specifications
Plumbing
3/4 inch to 1 1/4 inch I.D.
Drain Line
1/2 inch I.D.
Water Pressure
20 psi _ 120 psi (1.38 bar _ 6.89 bar)
Operating Temperatures
40° F _ 100° F (4.4° C _ 37.8° C)
Electrical Requirements
A properly grounded alternating current supply (110 VAC 60 Hz or 230
VAC 50 Hz) is required for the operation of this system.
Bypass Valve
The bypass valve enables you to bypass the system in situations of: emer-
gency leaks in the equipment, service calls.
Existing Plumbing Conditions
Plumbing should be free from lime and/or iron buildup. Piping that
contains large amounts of lime and/or iron should be replaced.
Additional Specifications
• Do not install this system where water is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system.
• This system must be installed in accordance with all applicable state
and local laws and regulations.
• The Commonwealth of Massachusetts Plumbing Code 248 CMR shall
be adhered to. A licensed plumber shall be used for this installation.
• This system must be installed in an area not affected by extreme heat,
cold or the elements. The selected installation area must be adequate
for easy service and accessibility.
• This system is designed to treat cold water only. The installation must
be on a cold water supply.
4
!
Important Note: This system
requires the use of the included
power supply (24 VDC).
!
Important Note: The manually
operated bypass valve enables
the conditioner to be isolated
from the water service line for
maintenance and service. It
also maintains the continuity of
the water supply when the
conditioner is disconnected.