Madas FM Manual Del Usaurio página 13

Tabla de contenido

Publicidad

8.0 - RATING PLATE DATA
The rating plate data (see example provided here) includes the following:
• Manufacturer's name/logo and address (possible distributor name/logo)
• Mod.:
= device name/model followed
by the connection diameter
• CE-51AR1070
= certification pin number
• EN 126
= Product reference regulation
• PS max
= Maximum pressure at which product operation is guaranteed
• Filtering
= Filtering
• (-40...+70) °C
= Temperature range within which product operation is guaranteed
= Conformity with Regulation (EU) 2016/426 followed by Notified Body No.
= In compliance with PED directive followed by the no. of the Notified Body
• year
= Year of manufacture
• Lot
= Product serial number (see explanation below)
• U1812
= Lot issued in year 2018 in the 12th week
• 7634
= progressive job order number for the indicated year
• 00001
= progressive number referring to the quantity of the lot
9.0 - FILTER SIZING EXAMPLE
Usage data
Q
= 270 [Nm
/h] Methane
3
n
P
= 2.6 [bar]
i
To use the diagram, you have to convert the usage
data to the diagram conditions (P
• Conversion to the flow rate at the diagram conditions:
Q
[Nm
n
Q
[Nm
/h] =
3
P
+ 1 [bar]
d
i
• Choosing the filter diameter:
Maximum flow rates in m
DN 15
m
/h
3
13.0
• Identify the Q
flow rate on the Gas line used and go up with a vertical line until you cross the straight line for the selected diameter
d
(see example diagram on page 48);
• From this newly identified point, move left until you cross the graph axis and read the ∆P
• Converting the ΔP
measured on the diagram at the system conditions:
d
∆P
[mbar] = ∆P
r
d
• Follow the same procedure in the diagrams on pages 49, 50 and 51 to calculate the pressure drop of the filters to the various
filtering points (50 µm -20 µm -10 µm).
Madas Technical Manual - REV. 0 of 10
=0) and vice versa.
1
/h]
270 [Nm
3
=
2.6 + 1 [bar]
/h of methane gas considering a max flow speed through the pipes of 20 m/s
3
DN 20
DN 25
m
/h
m
3
23.1
36.1
[mbar] x (P
+ 1) [bar] = 1.5 [mbar] x (2.6 + 1) [bar] = 5.4 [mbar]
i
Oct 2018
th
Mod.: FM DN 50
CE-51AR1070 - EN 126
Filtering: 50 micron
year: 2018
KEY
Q
n
Q
d
P
i
∆P
d
∆P
r
P
: Diagram tracing pressure
1
/h]
3
= 75 [m
/h]
3
DN 32
/h
m
/h
3
3
59.2
13
0051
0497
Lot:U1812
7634/00001
[Nm
/h]
3
: Usage flow rate
: Flow rate at the diagram conditions
: System pressure
: ∆P measured on the diagram
: ∆P normalised to the system condition
DN 40
m
/h
3
92.5
d
PS max: 6 bar
(-40...+70) °C
[m
/h]
3
DN 50
m
/h
3
145
FM-FGM

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

FgmCe-51ar1070

Tabla de contenido