Place the Aqua ✓ Nano on a flat counter surface near the sink. With the Wand
7.
pointing outward over the sink, turn on the water and divert it through the filter
by turning the lever on the Diverter Valve 90°. Check for leaks. To stop the flow
through the filter, turn off the faucet or turn the lever in the opposite direction.
8.
If needed, adjust the hose length between the Inlet Assembly and the Diverter
Valve to accommodate the cover. To make it longer, feed the tubing into the base
from the Diverter Valve end and pull it out at the inlet end.
To make it shorter, feed the tubing into the Base from the inlet end and pull it out
the diverter end. Do not pull the tubing too tightly over the filter cartridges as
this may restrict flow.
9.
Run water through the filter for 2 minutes to remove any small carbon particles ,
expel excess air and saturate the Media.