Technical Specifications - Pima DPS143 Instrucciones De Instalación

Tabla de contenido

Publicidad

DPS Standard and DPP Pet Immune Wireless PIR Motion
Detectors
The DPS (Standard) and the DPP (Pet immune) are wireless PIR (Passive Infra Red) motion detectors in FastLink technology, designed
for the FORCE Series intruder alarm systems. The FastLink communication is encrypted using true, 128-bit AES encryption for a high level
of security. Using the DPS/DPP requires the installation of a wireless receiver.
The two detectors are based on digital processing, and utilize an advanced movement detection algorithm. The DPS and the DPP can be
used in apartments, private houses and also in offices.
The DPP is immune to animals weighing up to 25 kilograms.
The DPS and the DPP have an elegant design. When detecting a movement the detectors transmit an alarm signal to the control panel.
The detectors have a tamper switch that alerts when their enclosure is opened or removed from the wall.
The DPS and the DPP transmit a supervision event when replacing the battery and also every 15 min. The two detectors alert on low
battery condition. For enrollment information, see the alarm system's Installation guide.
Cautions: the DPS and the DPP are based on wireless (RF) transmissions. Any wireless transmission can
be subject to RF interference and, although unlikely, this interference may cause the DPS and the DPP to
not operate as intended. RF transmissions will be attenuated by tinted glass, in wall isolation with metal
foils, metal objects, etc.

Technical specifications

 Frequencies (MHz):
o DPS/DPP143: 433.92
o DPS/DPP187: 868.95
 Battery: 1X CR123A, 3VDC, Lithium
 Battery Life: Up to Five Years (Typical Usage)
Content of the product package
 DPS/DPP detector
Mounting considerations
 Surface or corner mount the detectors at a height between 1.8m and 2.5m.
 Allow the widest possible angle for the detector's coverage pattern.
 Mount the detector where an intruder will most likely cross through the coverage pattern; the DPS and DPS detection range is 12m
at 90 degrees.
 Do not mount the detectors outdoors or where direct sunlight can reach it.
 Do not mount the detectors where there are extreme levels of heat and light from heaters and air conditioners, hot and cold drafts,
lightning, and moving headlights.
 Do not mount the DPP detector where pets can climb into the upper field of view.
How to install the DPS/DPP
1.
Release the screw at the bottom of the detector and remove the cover.
2.
Break the matching knock outs on the backplate for surface or corner mount; see the figures above.
3.
Fix the backplate onto a flat surface.
4.
Place the battery. Observe polarity!
5.
Set the jumpers; see below.
6.
Reassemble the detector: tilt it upwards, push it against the top part of the backplate first and then push the rest of it; see the
Cover placing
figure above.
7.
Fasten the detector's screw.
8.
Enroll the detector (refer to the FORCE's Installation guide).
9.
Test the detector using the
The LED
Color and state
Description
Green blinking
Battery OK, tamper closed.
Red 1 blink
Battery OK, tamper open.
Red 2 blinks
Low battery
The jumpers
Label
Jumper closed (on)
LED
The LED illuminates
SENS
Low sensor sensitivity (8m)
PULSE
Alarm signal will only be transmitted, if
two pulses are detected.
 Screws, mounting tapes
Test and Diagnostics
menu.
Jumper open (off)
The LED stays off
High sensor sensitivity (12m)
Alarm signal will only be transmitted, if
three pulses are detected.
 Sizes: 11 X 5.5 X 5.5 cm
 Weight: 110gr
 CE Compliance
 Temperature: -10 to +50 °C
 Humidity (Max.): up to 93% R.H., Non-condensing
 This guide
-2-

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dpp143Dps187Dpp187

Tabla de contenido