7
MAX function
The MAX function is activated by pressing the "MAX" button. The measured value currently displayed
corresponds to the largest measured value. Lower measured values are not displayed. Press the "MAX"
button again to deactivate the function.
8
Record measured values (RECORD)
An internal memory makes it possible to record measured
data during a measurement session. The stored data can be
read out for subsequent evaluation. The memory can hold
up to 16,000 measurements. Press the "RECORD" button
for 2 seconds to start recording. "RECORD" appears at the
bottom of the display. Press the button again for 2 seconds to
stop recording. "FULL" is shown on the display as soon as the
memory in the device is full.
!
Do not start measurement recording before the device has been securely set up and adjusted.
Measurements may be falsi ed if settings are changed during recording.
9
Clear memory
Press and hold the "LEVEL
in the memory. "CLR" appears on the display. Press and hold the "LEVEL
for 3 seconds to con rm that you wish to delete the data. The "CLR" display then
ashes for a short time. The delete operation is concluded as soon as the normal
display view appears again.
10
Transfer stored data (SEND MEMORY)
The software on the supplied CD must be installed on your PC before the stored data can be read out and
evaluated. Place the CD in the drive of your PC, start the installation program and follow the installation
routine.
After successful installation, start the application. Then
connect the supplied transfer cable to the PC interface on the
device. Connect the other end of the cable to a free port on
your PC. Press and hold the "SEND MRMORY" button for 3
seconds to transfer the data. "SENDING MEMO" appears on
the display and goes out again as soon as data transfer has
been completed.
!
Refer to the PDF le on the CD for information on installation
and operation of the supplied software.
" button for 3 seconds to completely delete the data
SoundTest-Master
2 sec
" button
3 sec
GB
11