⑧ - ⑫ Camera setting function switches
Use them by referring to each operation item.
⑬ Video output terminal
Used to give out the video signal. Connect this to the video input terminal of a monitor,
switcher etc. (To be terminated with 75-ohm impedance.)
⑭ External sync signal input terminal
Used to receive the GENLOCK (general lock) signal. For external synchronization,
input VBS or BBS signal.
⑮ External sync signal 75-ohm termination switch
Set to HIGH position when the GENLOCK signal is looped with T-shaped connector.
Usually, set at 75-OHM position.
⑯ Power indicator
Green LED lights up when power is supplied to the camera.
⑰ Terminal switch for RS-485
In RS-485 communication control, turn this switch to ON side for one-to-one control,
and turn it to OFF side for daisy-chain connection. (For use in daisy-chain connection,
turn ON the terminal switch by terminal connection equipment.)
⑱ RS-485 connection terminal block
Used for RS-485 connection.
⑲ AC24V/DC12V power input terminal
Input the power of AC21.6~26.4V or DC10.5~15V.
⑳ AC 230V power cable
Used to supply AC 230V power. AC 196-264V is acceptable.
Note: The camera has no power switch. Just plug in the power cable and the
camera gets started. To turn off the camera, just unplug the cable.
The socket-outlet shall be installed near the equipment and shall be easily
accessible.
E-4