Dwell Time - Beninca VE.KM1H Manual De Instrucciones

Espira magnética para detección de masas metálicas
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4.1 Sensitivity
When sensitivity is set, the frequency variation, which can be caused by a vehicle, can be calculated to preset the corresponding output on the detector.
The sensitivity is adjusted by means of Dip-switches 1 and 2, according to the double system, in 4 phases.

4.2 Dwell time

4.2 Dwell time
The dwell time can be adjusted by means of Dip-switch 3.
After the dwell time has elapsed, the status of "free loop" is displayed and a new comparison of the loop layouts is performed automatically. The dwell time of a channel
starts when the relevant loop is activated.
4.3 Frequency
4. 3The operating frequency of the detector can be selected on two levels. The frequency range is between 30kHz and 130kHz. The frequency depends on the inductivity
due to the loop shape, the number of loops, the power supply and the preset frequency level. The frequency level can be adjusted by using Dip-switch 4. After modifying
the frequency level, the layouts should be compared again by pressing Reset.
3. Connections
24V=
0V/GND
Sensitivity
Holding time
Relay operation principle (NC or NO)
Presence signal
4. Possible adjustments
Sensitivity level
1 low
(0,64% f/f)
2
(0,16% f/f)
3
(0,04% f/f)
4 high
(0,01% f/f)
Dwell time
5 minutes
Continuous
Frequency level
High
Low
0V 24V
28V
s
h
5'/
r
/
High
Frequency
Low
VE.KM1H
18
15
25
Pulse signal
Dip-switch
1
2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
Dip-switch
3
OFF
ON
Dip-switch
4
OFF
ON
5

Publicidad

Tabla de contenido
loading

Tabla de contenido