Clamp head measurement display (AC current)
1. Rotate function selection switch to the clamp head converter (AC
current) position.
2. Connect the black test probe to the COM input jack and the red
probe to the V input jack.
3. Select the different range of the clamp head converter to be AC30A
/ AC400 A / AC1500A. (for compatible FACOM clamps)
4. Press the «FUNC» key to select the corresponding measurement
range.
5. Reading the measured current value and the frequency value of the
clamp head converter from the LCD display.
Clamp head measurement display (DC current)
1. Rotate function selection switch to the clamp head converter
(DC current) position.
2. Connect the black test probe to the COM input jack and the red
probe to the V input jack.
3. Select the different range of the clamp head converter to be
DC30A / DC400 A / DC1500A. (for compatible FACOM clamps)
4. Press the FUNC key to select the corresponding measurement range.
5. Reading the measured current value of the clamp head converter
from the LCD display.
800.MACTOOLS
11