compressor at least 3 minutes to settle before restarting.
6. The unit stops when the ice basket is full and the "Ice Full" indicator will be on. Warning: Direct
sunlight or sunlight reflection may cause infared sensor malfunction. If the unit doesn't
stop even ice cubes obstruct sensor, move the unit where no sunlight.
7. Change water in the water reservoir every 24 hours to ensure a reasonable hygiene level.
If unit isn't to be used, drain all the water and dry the tank.
PROBLEM
"Add
Water"
indicator is on.
"Ice
Full"
indicator is on.
Ice cubes stick
together.
Ice
making
cycle is normal
but
no
ice
formed.
TECHNICAL PARAMETERS
Protection Type
Climate Type
Power
Ice Making Current
Ice Harvest Current
Refrigerant
Net Weight
Vesicant
Enclosure
WARRANTY INFORMATION
– WARNING: Keep ventilation openings, in the appliance enclosure or in the built-in structure,
clear of obstruction.
– WARNING: Do not damage the refrigerant circuit.
POSSIBLE CAUSE
Lack of Water.
Ice is full in basket.
The ice making cycle is
too long.
Water temperature in
inner tank is too low.
Room temperature or
water temperature in
inner tank is too high.
Refrigerant in cooling
system leaks.
Pipe in the cooling
system is blocked.
I
SN/N/ST/T
220-240V/50Hz
0.7A
1.0A
R600a/26g
8Kg
C
H
5
10
Plastic
SOLUTION:
Stop the ice maker, fill water, and press
"ON/OFF" button again to restart the unit.
Remove ice from ice basket. Continuous press
"Select" button 5 seconds, the unit could
make ice 10 cycles even "Ice" indicator is on.
Stop the ice maker, and restart it when the ice
blocks melt. Select the small size ice cube
selection.
Replace the water. Temperature of water
recommended at 8-32℃
The room temperature should be 10-43℃, water
temperature should be 8-32℃
Verify by a qualified technician.
Verify by a qualified technician.