WATER CONNECTIONS (CONT'D)
LOCATION
OF DRAIN
2˝
ELECTRICAL SYSTEM
The electrical system does not require general maintenance. The following wiring diagram is supplied for reference only.
MCP Series
If optional Purge Pump is installed
WATER LEVEL
ELECTRICAL SPECIFICATIONS OF MCP SERIES COOLERS
Fan Motor 120 V, 2.8 amps
Over ow Drain
1.
Slide the rubber washer over the over ow tting and push
through the hole in the bottom of the cooler from the top
side.
2.
Secure the drain from beneath the pan with the Lock Nut.
3.
Make sure the rubber washer does not twist while tighten-
ing, which could cause it to leak. DO NOT OVER TIGHT-
EN.
4.
If leakage occurs after reservoir is full, re-tighten the over-
ow tting until leaking stops. A small amount of silicone
caulk may be used if necessary.
5.
Attach a drain hose to the bottom of the tting if neces-
sary.
Water Level
Two inches of water should be maintained in the bottom of
the cooler to ensure suf cient water for correct operation of
the cooler.
The oat is factory-installed to maintain a 2 inch level of
water, but may require adjustment if shipping or installation
has caused the setting to shift.
Main Pump 120 V; 0.9 amps
Additional 0.9 amps
7