ENG
4
PRCD
The PRCD device is integrated to the power cord of the unit, close to the wall plug.
The PRCD device features two buttons; the small one is the "test" button and is used to check the
operational status of the PRCD. The bigger button is the "reset" and is used to rearm the PRCD after a
triggering event.
When plugging off the power cord a test needs to be perfomred to ensure proper operation of the
PRCD. Please follow the steps below:
Step 1:
Plug into power.
Press (small) "TEST" button. The (big) "RESET" button should pop-up.
Step 2:
Press the "RESET" button again. Do not use the device if it fails!
Step 3:
5
Care & cleaning
It is important to clean the merchandiser at least twice a year. In order to avoid mold formation,
odours, etc. product compartments must be thoroughly cleaned. The interior of the ICM should be
cleaned with a mildly soapy cloth and the glass surface using a window-cleaning agent.
*
optional feature
12
*
Prior to any cleaning (inside or outside the device) procedure,
unplug the ICM! Remove the plug and make sure that the
operator can check from any of the points which he has access
that the cable is unplugged.
Never use a water hose or high pressure jet to clean the cooler.
TEST button
RESET button