Dc And Ac Voltages [V]; Ac Voltages - Low Impedance [V Elec] - Chauvin Arnoux C.A 5210 G Manual De Empleo

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Connect the leads to the multimeter and connect it in parallel to the circuit to
be tested.
Place the selector switch on voltmeter (V) function (high impedance).
The instrument is in AC mode. Press the DC/AC button to select DC and vice
versa.
Automatic range selection : read the measured value.
Memorise the value, if necessary, by pressing the HOLD button.
C.A 5220 G only
If necessary, press the following buttons :
RANGE to select the ranges manually
MIN.MAX to read the min or max values
to switch on the backlight of the display
LOW IMPEDANCE: V elec
Identical procedure (as above) except for positioning the selector switch on
V elec.
DC VOLTAGES
V DC
Digital
resolution
Bargraph
resolution
V DC
Impedance
V elec
Impedance
Accuracy
Permitted
overload
(1) 4000 count display limited to 600V
DC and AC VOLTAGES
VOLTAGES WITH
400 mV
4 V
0.1 mV
1 mV
10 mV
100 mV
± 1 % reading ± 1 count
600 V rms and 900 V peak
40 V
400 V
10 mV
100 mV
1 V
10 V
10 MΩ
270 kΩ
21
600 V
(1)
1 V
100 V

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

C.a 5220 g

Tabla de contenido