Cleco mPro400GCD-P Manual De Instrucciones página 21

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

The required signal circuits are connected to these input/output connectors. The signal groups are not gal-
vanically connected to the power supply; galvanic isolation is required.
16 digital inputs/outputs, optically isolated for 24 V level/0.5 A
8 inputs/8 outputs/2 +24 VDC/2 GND
Output current: 500 mA per output, 2000 mA total
A single device must not require a current of more than 500 mA. The current monitor switches off the
ATTEN-
output in the event of an overcurrent.
TION!
Pin
Signal X9
12
GND-int
11
GND I/O0–3
10
Output O3
9
Output O2
8
Output O1
7
Output O0
6
Input I3
5
Input I2
4
Input I1
3
Input I0
2
+24 VDC A0–A3
1
+24 VDC-int
Connectors that use an internal 24 V power supply
(Primary, Master)
Inputs
Internal 24 V power supply for the controller.
Pin 11 and 23 (common GND) serve as a "return line" for the outputs.
Pin 11 and 23 must be connected to Pin 12 or 24 with jumpers.
Outputs
Internal 24 V power supply for the controller
Pin 2 and 14 (common output) are the voltage source for the inputs.
Pin 2 and 14 must be connected to Pin 1 or 13.
EN
Pin
Signal X10
24
GND-int
23
GND I/O4–7
22
Output O7
21
Output O6
20
Output O5
19
Output O4
18
Input I7
17
Input I6
16
Input I5
15
Input I4
14
+24 VDC A4–A7
13
+24 VDC-int
21
2x12 pin Phoenix MCD 0.5/24-G1-2.5
Order No. S981211
X9
Mating connector
Phoenix FK-MC 0.5/12-STZ3-2.5
Order No. S981211
P2300HW
2018-03
X10

Publicidad

Tabla de contenido
loading

Tabla de contenido