Pause function using momentary switch
You can pause the fan for one hour by engaging an exter-
nal momentary switch. This can be connected as shown in
diagram 3 on page 7.
With this function selected, you will be unable to use the
delayed start via switched live (lighting) function connected
to SL
Activation
1 Press the Speed + and Humidity Mode buttons
simultaneously(the blue and yellow LEDs flash quickly).
2 Press the timer button and hold it in for 5 seconds until
the 5 min LED comes on.
3 Press the Speed + and Humidity Mode buttons at the
same time (The blue and yellow LEDs stop flashing).
Deactivation
1 Press the Speed + and Humidity Mode buttons
simultaneously (the blue and yellow LEDs flash quickly).
2 Press the timer button and hold it in for 5 seconds until
no timer run-on LEDs are illuminated.
3 Press the Speed + and Humidity Mode buttons
simultaneously (the blue and yellow LEDs flash quickly).
SPEED
TIMER
S
CONSTANT
TIMER
5
MIN
15
30
HUMIDITY
SILENT
MAX
SPEED
TIMER
S
CONSTANT
TIMER
5
MIN
15
30
HUMIDITY
SILENT
MAX
EN
11