Descargar Imprimir esta página

Dieffematic EKOS M2 230 S Istrucciones De Uso página 6

Publicidad

Idiomas disponibles

Idiomas disponibles

GB
1
2
3 4
5
6
7
8
LED STATE
L1
STATE Led
Lights when the unit is powered
L2
Led RADIO ON
when accessing memory in radio
L3
Led PROG. TIMES
on flashing in programming
L4
Led PHOTO CLOSING
on with the safety contact closed
L5
Led PHOTO OPENING
on with the safety contact closed
L6
Led STOP
on with the safety contact closed
L7
Led START
on when you give an impulse
EKOS 230 M2 S
17 18 19 20
9
10
11 12 13 14 15 16
TRIMMER T1
The Trimmer Power regulates
the power and sensitivity in
working.
TRIMMER T2
The Trimmer Power Slow
regulates the power and
sensitivity in slow down mode.
TRIMMER T3
The Trimmer Break regulates the
break time from 3 to 120 sec
TERMINAL
TIP.
1 - 2
230V ~ POWER 230Vac
3 - 4
230V ~ FLASH ( Max output 40W )
5-6-7
230V ~ ENGINE 1 (5-6 input condensator)(7 com)
8-9-10
230V ~ ENGINE 2 (8-9 input condensator)(10 com)
11-12
NC
12-13
NC
14-15
NC
15-16
NO
17-18
12V ~
19-20
12Vdc
BUTTON P1
RADIO PROG, for storage remote controls
BUTTON P2
PROG TIME, for storage the stroke
JUMPER J1 =
Selection storage radio INTERNAL EXTERNAL
-
You can insert the external receivers with the connector CRX. So you
+
can increase the memory or change the frequency.
Insert bridge.
TECHNICAL FEATURES
POWER
POWER ENGINE
OUTPUT ACCESORIES
TIME FOR AUTOMATIC CLOSE
TIME FOR MANEUVER
NR CODES STORABLE
TRANSMITERS TYPE
FREQUENCY
TEMPERATURE TO WORK
SENSIBILITY
HOMOLOGATION
DESCRIPTION
Closing PHOTOCELLS ( if not use make the bridge )
Safety band or opening PHOTOCELLS ( if not use make the bridge )
STOP Contact ( if not use make the bridge )
START Contact
Power service or accessories 12Vac 250mA
Electric Lock OUTPUT
BUTTON PG1
GATE1 For the programming stroke of the first leaf
or start command.
BUTTON PG2
GATE2 For the programming stroke of the second
leaf or pedestrian opening.
R
E
R
P
E
M
P
U
M
N
O
N
O
230V AC +/- 10%
550 W
12V AC 250mA
5 a 120 sec
3 a 120 sec
254 code
Fix\Roll-code
433.92 / 868 Mhz
-20 a 70°C
Better of –100dBm
Conf ETS 300-220/ETS
300-683
INTERNAL
EXTERNAL
J
U
J
JUMPER
JUMPER
F
F
F
O
F
O
OFF
OFF
ON
ON

Publicidad