Indoor unit condensed water drainage
The indoor unit condensed water drainage is fun-
damental for the success of the installation.
• Place the drain hose below the piping, taking
care not to create siphons.
• The drain hose must slant downwards to aid
drainage.
• Do not bend the drain hose or leave it pro-
truding or twisted and do not put the end of
it in water. If an extension is connected to the
drain hose, ensure that it is lagged when it
passes into the indoor unit.
• If the piping is installed to the right, the pipes,
power cable and drain hose must be lagged
and secured onto the rear of the unit with a
pipe connection.
• Insert the pipe connection into the relative
slot.
• Press to join the pipe connection to the base.
Installation of the pipes
After having connected the pipe, install the con-
nection cables. Now install the drain pipe. After
connection, lag the pipe, cables and drain pipe
with the insulating material.
1.
Arrange the pipes, cables and drain hose
well.
2.
Lag the pipe joints with insulating material,
securing it with vinyl tape.
3.
Run the bound pipe, cables and drain pipe
through the wall hole and mount the indoor
unit onto the upper part of the mounting
plate securely.
4.
Press and push the lower part of the indoor
unit tightly against the mounting plate.
55