The maximum depth of cabinet installed above cooktop
is 13" (33cm).
Depth from Back Wall
Cabinet 13" (33cm) max.
Hood Depth - 24" (61cm) max.
Above Counter - 30" (76 cm) min. to
Combustible Surface
NGM30 - 30" (76cm) min.
NGM36 - 36" (91cm) min.
Centered Over Cooktop
18" (46cm) min.
Left Side
Rear Wall - 2" (5cm)
12" (33cm) min.
Installed Dimensions (from cooktop edges
Figure 1:

Countertop Requirements

30" Models
measurement in inches/mm

Island Installation

3"
(76.2)
Front
2 1/8"
(54)
9001079091 RevA
Right Side
12" (33cm) min.
gas
connection
3 1/8"
Back
(79.4)
3"
(76.2)
measurement in inches/mm
NOTE:
All measurements given have to be precisely followed. If
nonstandard cabinets are used, make sure they are
installed with minimum dimensions shown in Figure 1 and
Figure 2.
Plan the installation of the unit so that the power cord, gas
shut-off valve and gas pressure regulator are accessible
from the front of cabinet.
)
36" Models

Mounting Requirements

Use the mounting brackets supplied. See "Install the
Cooktop" on page 6 for further details.

Ventilation Recommendations

We strongly recommend the installation of a ventilation
hood above this appliance. The hood must be installed
according to instructions furnished with the hood.
gas
connection
measurement in inches/mm
Figure 2: Cutout Dimensions
English 5