Recommended mounting hardware for wood studs are 1/4" x 2" hex head lag bolts.
Recommended mounting hardware for concrete walls are 1/4" x 1-3/4" concrete hex screws or
1/4" x 1-7/8" concrete anchors
WARNING: Danger of electrical shock or injury. Turn OFF power at the panelboard or load center before
working inside the equipment or removing any component. Do not remove circuit protective devices or
any other component until the power is turned OFF.
WattStation Wall Mount User Manual
Torque Specification Table:
COMPONENT
M5 x 0.8 screw
#12 thread-cutting screw
10-32 UNF screw
6-32 UNC screw
Fuse block lugs
Field wiring lugs
Din-rail mounted terminal block
lugs
Contactor lugs
Ground bar lugs
M3 x 0.5 screw
#8 thread cutting screw
3/4" cable strain relief fitting

2.2.2 Installation

Step 1: Carefully unwrap the packaging and make sure the following items are present:
-Wall Mounted WattStation unit
-Mounting wall bracket
-Key for WattStation mounting lock
4
 
TORQUE VALUE
30 in-lb
30 in-lb
35 in-lb
12 in-lb
45 in-lb
50 in-lb
12 in-lb
50 in-lb
35 in-lb
12 in-lb
30 in-ib
Hand-Tight + 1/4 turn