there should be an electric outlet within 1 meter (3 feet) of your central vacuum
unit. once the appliance is installed in a suitable location, connect your central
unit to an electric outlet on an dedicated* grounded circuit. Do not use extension
cords or modify the length of your vacuum cleaner's power cord.
dedICated* grounded CIrCuIt
• north america
120 V / 240 V all models : 15 a
• european continent and other
220 V / 240 V model DL200SV : 10 a
220 V /240 V all other models : 8 a
your central vacuum cleaner has a thermal safety device or a circuit breaker to
protect against any over voltage or electrical defect. If that protection should fail,
contact your authorized service center.
*please reserve a circuit breaker dedicated only to the connections for your
central vacuum.
If you find that installing your vacuum cleaner is too difficult, ask your service
center to install it for you. When in doubt, it is better to have the work done by a
professional and ensure that the unit is properly installed. any installation that
does not comply with the specified norms could alter or invalidate the warranty.
Electric Connections
Installation
13