Place the machine with the wheels toward the vehicle.
Lean the machine back and rest the loading wheel on
the vehicle bed. Lift the front of the machine and slide it
onto the vehicle (Figure 15). Use care not to damage
electrical cord or foot switch hose.
Be aware of the machine weight – depending on the ma-
chine and cable, the machine may weigh 194 lbs. (98 kg)
or more. Use proper lifting techniques. More than one
person may be required.
Figure 15 – Loading Onto Vehicle

Storage

The drain cleaner must be kept dry and
WARNING
indoors or well covered if kept outdoors. Store the ma-
chine in a locked area that is out of reach of children and
people unfamiliar with drain cleaners. This machine can
cause serious injury in the hands of untrained users.

Maintenance Instructions

WARNING
FOR/O-OFF/REV switch should be O-OFF and ma-
chine unplugged before performing any mainte-
nance.
Always wear safety glasses and other appropriate
protective equipment when performing any mainte-
nance.
278-109-441.10_REV. B
K-750R Drain Cleaning Machine

Cleaning

After each use, clean the machine. A mild detergent or
antibacterial solution can be used if desired. Do not
use solvents, abrasives or other harsh cleaning agents.
Machine – Use a damp, soft cloth to wipe off the ma-
chine. Do not submerge or flush the machine with water.
Do not allow water to enter motor or other electrical
components. Make sure unit is completely dry before
plugging in and using.
Drum and Cable – Flush the drum and cable with water
after every use to prevent damaging effects of sedi-
ment and drain cleaning compounds. Drain debris from
drum by tipping machine forward after every use to re-
move sediment, etc. which can corrode cable. Allow to
dry to reduce cable corrosion.

Lubrication

Lubricate machine with general purpose grease at grease
fitting located at connection of guide tube and drum (see
Figure 16). If drum is changed or removed, once a week if
used every day: once a month if used less. Lubricate
cable coupling plunger pins with light machine oil.
Figure 16 – Grease Fitting Location

Changing Cable

Remove Cable

1. Pull entire cable from drum, so coupling can be ac-
cessed. Disconnect cable. (See Figure 17.)

Installing Cable

Do not remove the band/staples from the cable carton.
The cable is under tension and can whip or strike if
released. Only use RIDGID catalog number 37754, C-24
HD
5
/
" x 100' cable in K-750R Drain Cleaning Machine.
8
1. Retrieve male coupling end of cable through the cen-
ter hole of the carton and pull approximately 6' of
cable from the carton.
13

Publicidad