After Usage

Observe the instructions in the section entitled "Safety".
Never leave liquid in the device.
1. Remove the plant protection product tank from the device and close it with the original
cap.
2. Fill the 1-liter bottle [14] included in the scope of delivery with water and screw on the
tank cap [2] belonging to the dosing system (Fig. 11).
3. Switch to "MODE: C" by operating the selector switch [20] on the operating unit [8]. Operate
the switch [21] on the spray gun [4] until clear water escapes from the nozzle (Fig. 12).
+
Spray this liquid on untreated grape wood. Do not allow it to get on the ground or in
water.
+
Never spray longer than 60 seconds in "Mode: C". Parts of the device
may overheat or get damaged!
+
Protect the pump against drying! Leave the remaining water in the device.
Collect and dispose of the residual liquid according to all applicable laws, require-
ments and regulations. Observe the instructions of the spray product manufacturer!
4. Set the device main switch [16] on the operating unit [8] from "ON" to "OFF" (Fig. 13).
5. Clean all components of the dosing system that came into contact with the plant protec-
tion product to prevent that it sticks on the device and jams it.
+
Please note in particular the aeration valve [28] in the tank cap [2] and the nozzle [25]
(Fig. 14).
6. Protect the device from frost! If needed it is possible to use a commercially available
antifreeze. Store the device in a dry environment and protect it from direct sunlight.
Clean the protective equipment and yourself every time after usage.