Guardian Fall Protection SRL Serie Manual De Instrucciones página 14

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

!
ALWAYS adhere to the following warnings and specifications when using LE SRLs.
WARNING
When used in combination with a compatible shock absorber extension, Edge Series SRLs are
tested and certified for horizontal use over a steel edge without burrs. Edge Series SRLs may be
used over similar surfaces, such as metal sheeting or other steel formations.
The allowable angle of redirection of the lifeline portion of Edge Series SRLs at the leading edge
of a fall hazard MUST be at least 90° (see Image 1).
Anchor point MUST be situated no lower than the leading edge of applicable fall hazard(s).
Prior to use, a Competent Person MUST calculate adequate fall clearance (see pg. 6).
ALWAYS attach to anchorage connector that will allow for required setback distance (see
Image 2).
Setback distance: As determined by product testing, Guardian Fall Protection Edge Series
SRLs MUST be installed a MINIMUM 6' (1.8m) from the leading edge of applicable fall
hazard(s).
Edge Series SRLs may be used in combination with horizontal lifelines. All installation, set-up,
and use of horizontal lifelines must be done under the supervision of a Qualified Person.
NEVER work on the far side of an opening that is opposite the Edge Series SRL anchorage point.
In the event of a fall over the edge, special rescue measures may be necessary. Always account
for use of Edge Series SRLs in job site rescue plan developed by job site Competent Person.
X≤90°
12
X≥90°
Image 1
Leading Edge
Setback Distance
Image 2

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

109091091010912109151093010932 ... Mostrar todo