DISPLAY ACTIVATION AND SETTING
Press any key for about 1 second to activate the display.
After the last impulse, the display remains on for a number seconds which can be set (pre-
set value: 30 seconds). During the 10 minutes after being switched off, the display can be
reactivated by slightly pressing a key and the last screen can be visualised. After these 10
minutes (prolonged switch-off), it will be necessary to keep any key pressed for a longer
time (about 1 second). Then, the system will start and will show the System Status screen.
Pre-set value change:
Main menu / Settings / Display > Switch-off
Set the required value* (min 10 sec. – max 90 sec.) and then press SAVE.
In the programming phase it is advisable to set a high value (60 to 90 seconds), while
a low value (10-30 seconds) during daily use is suffi cient and helps prolong the life of
the batteries.
Adjustment of the display brightness:
Main menu / Settings / Display > Brightness
Set the required value* (min 00 – max 10), then press SAVE.
*Use the UP/DOWN keys to set the required value.
Press SELECT to move from one box to the other inside the same screen.
RADIO SETUP
Command Delay: When the programming implies sending a sequence of commands (e.g.
opening of blinds in several rooms), the time intervals between these commands are pre-
set in seconds.
Repeat Count: when a command is sent simultaneously to more than one device (group or
scenario) both in the automatic and in the manual mode, the execution of the command
by the motor could be compromised by external factors. This is why the system offers the
possibility of setting a number of command repetitions
(Repeat count)
at a certain time
interval
(Repeat delay).
Repeat Delay: the time interval between one repetition of the same command and the
next.
All these values can be set as you wish:
Command Delay: preset-value: 4 – this value can be set from 2 to 30 seconds.
Repeat Count: preset-value: 3 – this value can be set from 2 to 10.
Repeat Delay: preset-value: 1 – this value can be set from 1 to 10 minutes.
TM2 X TT-50
26
A4518_6H04_Rev.A