MODEL EI500 Series
Installation and User Instructions
WARNING
Risk of Fire or Electric Shock
• Disconnect power at the circuit breaker(s) or disconnect
switch(es) before installing or servicing.
• Installation and/or wiring must be in accordance with national and
local electrical code requirements.
• Use COPPER conductors ONLY.
NOTICE
• No user-serviceable parts.
• The internal battery requires up to 30 minutes to charge. If the
battery is not charged and power is lost, schedule information
may have to be re-configured.
Features
• 7-Day Control Schedule
• Up to 7 ON and 7 OFF Events per day
• Works with multiple load types including: incandescent,
compact fluorescent, HID, motors, and heaters
• Available in White, Ivory, and Light Almond
Ratings
• All Ratings 125 VAC, 60 Hz
• 15 A / 1875 W Resistive / Heater
• 15 A, General Purpose
• 8 A / 1000 W Tungsten
• 8 A / 1000 VA Inductive / STD Ballast
• 500 VA Electronic Ballast
• 1/4 HP Motor
Leads
• Black = Line
• White = Neutral
• Red = Load
• Green = Ground
Installation Instructions
1. Remove wall plate and disconnect
existing light switch.
2. Make
sure
both
"neutral" wires are present in the
junction box. If both wires are not
present, additional wiring will be
necessary before installation can be
completed.
3. Connect red timer wire to wire from
fixture using wire connector.
4. Connect
black
timer
wire to the "hot" (usually
black or red) wire in
junction box using wire
connector.
5. Cut white
wire
in
j u n c t i o n
box
(or
open splice) and strip
½" of insulation on both
wires.
"hot"
and
Electronic
7-Day
In-Wall
Time Switch
6. Connect white timer wire to white wires in junction box
using wire connector.
7. If the wall switch you are replacing had separate grounding
conductors connected to the GREEN screw on the switch,
make sure to connect these to the green wire from the timer
with a wire connector.
8. Check that all wire connections are secure.
9. Place all wires inside junction box.
10. Fit timer into junction box and install using two (2) mounting
screws (furnished).
11. Reconnect the electrical power.
Setting the Clock
1. Press and HOLD the CLK (Clock) button.
2. Press the DAY button until the display shows the current day.
3. Press the HOUR button until the display shows the current
hour.
4. Press the MIN (Minute) button until the display shows the
current minute.
Setting Programs
1. Press the PROG (Program) button once. The
display will look as shown at the right.
You will now set up the time in which you
want your device turned ON.
The number 1 in the lower left hand corner
indicates that you are now programming
EVENT 1.
2. Press the DAY button repeatedly until the display shows the
day(s) when you want the timer to turn on. The options are:
- All days of the week (MO TU WE TH FR SA SU)
- Individual days of the week (MO etc.)
- Weekdays only (MO TU WE TH FR)
- Weekends only (SA SU)
3. Press the HOUR and MIN (Minute) buttons
to set the time when you want the timer to
turn on.
4. Press the PROG (Program) button again. The
display reads as shown at the right.

Publicidad

loading

Resumen de contenidos para Intermatic EI500 Serie

  • Página 1 MODEL EI500 Series Electronic Installation and User Instructions 7-Day WARNING Risk of Fire or Electric Shock In-Wall • Disconnect power at the circuit breaker(s) or disconnect switch(es) before installing or servicing. Time Switch • Installation and/or wiring must be in accordance with national and local electrical code requirements.
  • Página 2 LIMITED ONE-YEAR WARRANTY If within the warranty period specified, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, free of charge. This warranty is extended to the original household purchaser only and is not transferable. This warranty does not apply to: (a) damage to units caused by accident, dropping or abuse in handling, acts of God or any negligent use;...
  • Página 3 MODÈLE SÉRIE EI500 Minuterie Instructions d’installation et mode d’emploi électronique AVERTISSEMENT Risque d’incendie ou de choc électrique encastrée • Débrancher l’alimentation au niveau des disjoncteurs ou des section- neurs avant de procéder à l’installation ou à l’entretien. • L’installation et/ou le câblage doivent être conformes aux exigences du 7 jours code de l’électricité...
  • Página 4 GARANTIE LIMITÉE UN AN Si, dans la période de garantie spécifiée, ce produit tombait en panne dû à un vice de matériau ou de fabrication, Intermatic Incorporated le réparera ou le changera, à sa seule discrétion, et ce gratuitement. La présente garantie s’étend à l’acheteur particulier initial uniquement et n’est pas transférable.
  • Página 5: Interruptor Temporizador Electrónico

    Serie MODELO EI500 Interruptor Instrucciones de instalación y para el usuario temporizador ADVERTENCIA R iesgo de incendio o descarga eléctrica electrónico • Desconecte la energía desde los disyuntores o desde los interruptores antes de realizar la instalación o el mantenimiento. de 7 días •...
  • Página 6: Garantía Limitada De Un Año

    GARANTÍA LIMITADA DE UN AÑO Si dentro del período de garantía especificado, este producto presenta fallas a causa de defectos en los materiales o en la mano de obra, Intermatic Incorporated lo reparará o lo reemplazará, a su exclusivo criterio, sin cargo. Esta garantía se extiende solo al comprador doméstico original y no es transferible.