Descargar Imprimir esta página

Sony HMI-3000MT Manual Del Usaurio página 18

Ocultar thumbs Ver también para HMI-3000MT:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 66
3. The leakage current could increase when connected to
other equipment.
4. For this particular equipment, all accessory equipment
connected as noted above, must be connected to mains
via an additional isolation transformer conforming
with the construction requirements of IEC60601-1
and providing at least Basic Insulation.
5. This equipment generates, uses, and can radiate radio
frequency energy. If it is not installed and used in
accordance with the instruction manual, it may cause
interference to other equipment. If this unit causes
interference (which can be determined by unplugging
the power cord from the unit), try these measures:
Relocate the unit with respect to the susceptible
equipment. Plug this unit and the susceptible
equipment into different branch circuit.
Consult your dealer. (According to standard IEC60601-1-
2 and CISPR11, Class B, Group 1)
HMO-CA50M : Head Mounted Display Cable
The HMI-3000MT is intended for use in the electromagnetic environment specified below.
The customer or the user of the HMI-3000MT should assure that it is used in such an environment.
Emission test
RF emissions
CISPR 11
RF emissions
CISPR 11
Harmonic emissions
IEC 61000-3-2
Voltage fluctuations/
flicker emissions
IEC 61000-3-3
Warning
If the HMI-3000MT should be used adjacent to or stacked
with other equipment, it should be observed to verify
normal operation in the configuration in which it will be
used.
18
List of cables used for EMC test
Type of cable
Guidance and manufacturer's declaration-electromagnetic emissions
Compliance
Group 1
Class B
Not applicable
Not applicable
Important EMC notices for use in the
medical environments
• The HMI-3000MT needs special precautions regarding
EMC and needs to be installed and put into service
according to the EMC information provided in this
instructions for use.
• The portable and mobile RF communications
equipment such as cellular phones can affect the
HMI-3000MT.
Warning
The use of accessories and cables other than those
specified, with the exception of replacement parts sold by
Sony Corporation, may result in increased emissions or
decreased immunity of the HMI-3000MT.
Specifications
5 m, Shield cable
Electromagnetic environment-guidance
The HMI-3000MT uses RF energy only for its internal
function. Therefore, its RF emissions are very low and are
not likely to cause any interference in nearby electronic
equipment.
The HMI-3000MT is suitable for use in all establishments
other than domestic and those directly connected to the
public low-voltage power supply network that supplies
buildings used for domestic purposes.

Publicidad

loading

Este manual también es adecuado para:

Hmm-3000mt