The positioning and electrical and gas installation should always be carried out by an AUTHORISED
TECHNICIAN, observing the standards of each country.
It is advisable to install an extraction hood for the optimum operation of the appliance.
Place the appliance in a well-ventilated place.
Level and adjust the height of the appliance (FIG. 1)
An AUTHORISED TECHNICIAN should always carry out the appliance's electrical connection.
The legal standards in force in each country on connections to the mains should be taken into account.
Check that the mains voltage corresponds to that indicated on the nameplate.
Use cable sleeves made out of polychloroprene or other similar materials (H05RN-F), for the
connection.
Put an autonomous power switch with fuses into the mains socket, with a minimum distance
between contacts of at least 3 mm.
It is obligatory to earth the appliance. The manufacturer will not be held liable for damage originated by
failure to observe this requirement
The section of cable sleeve and the rating of the fuses to be installed in the power switch are
indicated in diagram no. 2.
To access the appliance's electrical connection terminal strip (FIG 2) loosen the switchboard cover screws.
Pass the cable sleeve through the stuffing box located in the switchboard and connect it to the terminal
strip.
VERY IMPORTANT: Before putting the switchboard top on, fasten the electric supply cable tightly to the
stuffing box.
When several appliances are installed in series, they should be earthed to each other using the point
assigned for this purpose, located in the rear part of the appliance.
Usage
When the appliance has been installed, clean the surface of the grill. Use water and detergent, do not
use abrasive products, especially in those with hard chrome plating, and block the fat outlet.
Turning the resistors on and off
D)
Activate the power switch.
E) Turn the adjustment thermostat control clockwise until pilot light 5 turns on.
F)
Turn the adjustment thermostat control clockwise to the required position (TABLE 2).
G) To disconnect, turn the thermostat control anticlockwise to position 1- OFF (•).(FIG 3)