20) EIT: EIT Insert - As mentioned above (6), the event information table can be chosen
whether to insert into the TS or not under this menu. If yes, the EIT information set above (6)
will be displayed on the TV screen. Language Code – to set the EIT language For example,
code of the English language is eng. If you set the code as eng, the EIT displayed will be in
English language.
21) Save Config: Yes/No-to save/give up the adjustment of setting.
22) Load Saved CFG: Yes/No-to load/ not to load the saved configuration.
23) Reset all sets: Yes/No-choose/not choose the factory's default configuration.
24) LCD Time out: A time limit that LCD will light off. Choose among 5s, 10s, 45s, 60s, 90s and
120s (seconds).
25 Key Password: User can set a 6-digital password used to unlock the keyboard.
26) Lock Keyboard: Choose Yes to lock the keyboard, then the keyboard cannot be applicable.
It is required to input the password to unlock the key board. This operation is one-off. (If
forgetting your password, please use the universal code "005599".)
27) Product ID: User can view the serial number of this device. It is read-only and unique
28) Version: It displays the version information of this device. Encoder Modulator: the name of
the device; SW: software version number; HW: hardware version number. User can also press
ENTER again to view the published time of this device.
Appendix
Modulation
FEC
Constellation
1/2
The weak ability of error-correcting and anti-interference in this area
2/3
QPSK
3/4
5/6
6.22
7/8
6.53
1/2
7.46
2/3
9.95
16QAM
3/4
11.19
5/6
12.44
7/8
13.06
1/2
11.19
2/3
14.92
64QAM
3/4
16.79
5/6
18.66
7/8
19.59
6MHz Bandwidth
Guard Interval
1/4
1/8
1/16
1/32
6.03
6.22
6.58
6.78
6.91
7.31
7.54
7.25
7.68
7.91
8.29
8.78
9.04
11.05
11.70 12.06
12.44
13.17 13.57
13.82
14.63 15.08
14.51
15.36 15.83
12.44
13.17 13.57
16.58
17.56 18.09
18.66
19.76 20.35
20.73
21.95 22.62
21.77
23.05 23.75
Table 1 Channel output max. capacity in Mbps
7MHz Bandwidth
Guard Interval
1/4
1/8
1/16
1/32
5.80
6.45
6.83
7.03
6.53
7.25
7.68
7.91
7.25
8.06
8.53
8.79
7.62
8.46
8.96
9.23
8.70
9.67
10.24
10.55
11.61 12.90
13.66
14.07
13.06 14.51
15.36
15.83
14.51 16.12
17.07
17.59
15.24 16.93
17.93
18.47
13.06 14.51
15.36
15.83
17.41 19.35
20.49
21.11
19.59 21.77
23.05
23.75
21.77 24.19
25.61
26.39
22.86 25.40
26.89
27.71
8MHz Bandwidth
Guard Interval
1/4
1/8
1/16
1/32
6.03
6.64
7.37
7.81
8.04
7.46
8.29
8.78
9.05
8.29
9.22
9.76
10.05
8.71
9.68
10.25
10.56
9.95
11.06
11.71
12.06
13.27
14.75
15.61
16.09
14.93
16.59
17.56
18.10
16.59
18.43
19.52
20.11
17.42
19.35
20.49
21.11
14.93
16.59
17.56
18.10
19.91
22.12
23.42
24.13
22.39
24.88
26.35
27.14
24.88
27.65
29.27
30.16
26.13
29.03
30.74
31.67