3
Conduit Hole
LED Tray
Lens Cover
Mounting Bracket
4
6
ELECTRICAL CONNECTIONS
STEP 1:
Make the following Electrical Connections to the lever nuts:
a. Connect the black luminaire lead to the line supply lead.
b. Connect the white luminaire lead to the neutral supply lead.
c. Connect the green/yellow luminaire lead to the supply ground lead.
d. If dimming is used; connect the violet dimming positive lead to the
supply dimming positive lead. If dimming is not being used, ensure to
cap off the violet lead
e. If dimming is used; connect the grey dimming negative lead to the
supply dimming negative lead. If dimming is not being used, ensure to
cap off the grey lead
© 2015 Cree, Inc. All rights reserved. For informational purposes only. Content is subject to change.
See www.cree.com/lighting/products/warranty for warranty and specifications. Cree® is a registered trademark, and the Cree
logo is a trademark of Cree, Inc.
2 of 2
Mounting Brackets
5
Loosen (2) Screws
Hinges
CEILING MOUNT USING MOUNTING
BRACKETS (OPTIONAL)
Plug
Mounting Brackets are NOT provided with
luminaire, they are sold separately.
STEP 1:
Attach brackets to ceiling using (2) customer
supplied #10 size minimum screws.
NOTE: It is recommended that the dimensions
between brackets equal about 70-80% of the
luminaire's length. The luminaire will engage to the
mounting brackets at any point along it's length,
except where there are latches. See Figure 3.
STEP 2:
Insert one side of the luminaire housing into the
mounting brackets as shown in Figure 4.
Mounting Bracket
STEP 3:
Push up on the luminaire and then press in on the
mounting bracket until the mounting bracket snaps
into place. See Figure 5.
STEP 4:
Remove lens cover by unhinging the latches and set
cover aside to reinstall later.
STEP 5:
Loosen (2) screws and carefully let the LED Tray
hang down from hinges. See Figure 6.
STEP 6:
Insert customer supplied liquid tight conduit and
liquid tight conduit fitting into desired conduit
hole located on the end of the housing. Bring
in customer supplied cord and make wiring
connections per "Electrical Connection" section.
See Figure 3.
NOTE: Insert supplied plug into unused conduit
hole.
STEP 7:
Bring LED Tray back into housing and secure by
tightening screws that were loosened in Step 5.
STEP 8:
Reattach lens cover removed in Step 4 and secure
using latches.
LINE
GREEN
NEUTRAL
VIOLET
GREY
LUMINAIRE
LINE-BLACK
GROUND-
GREEN/YELLOW
NEUTRAL-WHITE
DIM (+) VIOLET
DIM (-) GREY
www.cree.com/lighting
LPN00205X0001A1_A