FIG. B: HEAD ASSEMBLY
Upper cover
Glide
screws (×4)
(Inside
cover.)
1. Replace stem assembly and retighten retention nut.
Reattach trigger lever.
As needed: Clean the inline strainer (Fig. D) when
solution flow is visibly reduced. To clean the filter, loosen
the strainer assembly nut, and remove the strainer and
strainer washer. Rinse these items in clean water and
reassemble the strainer. It is not usually necessary to
replace the inline filter element. Be sure to include the
nylon washer when reassembling, and take care not to
over-tighten the strainer assembly nut.
To maintain appearance, wipe exterior surfaces with a
damp cloth.
SERVICING
The Upholstery Pro is designed to allow easy in-the-field
service to the glide and the trigger valve with basic hand
tools in just a few minutes. If replacement becomes
necessary, rebuild kits and replacement parts are
available from your Sapphire distributor or
from Sapphire Scientific at 800-932-3030.
Replacing the glide
Have on hand a Glide and O-ring
replacement kit (part no. S13-01705).
1. Remove the four cover screws (Fig. B)
and lift off the cover.
2. Remove the four glide screws (Fig. B)
and remove the glide and the O-ring seal.
Discard.
3. Install new O-ring into sealing edge of
new glide. Put new glide into head. Make
sure that the O-ring is in place.
07-02087B F436-P
Lower cover
Trigger valve body
(13-01690)
Cover screws
(×4)
Glide and O-ring seal
(S13-01705)
FIG. D: SOLUTION LINE COUPLING ASSEMBLY
FIG. C: HEAD (BOTTOM VIEW)
Trigger lever
Trigger lever lock
4. Replace glide screws and tighten; then replace
cover and tighten with cover screws.
Servicing the trigger valve
If the trigger leaks or no longer releases sufficient
solution and you have determined that the glide is not
plugged or damaged (see "Check Glide Assembly," p. 1)
the trigger may need service. Two repair options are
available.
Option A: Rebuild the trigger valve.
A stem replacement kit (part no. 48-064) is available
from your Sapphire distributor. The parts included in this
kit are shown in Fig. E.
1. Remove the nut and bolt from the trigger lever and
remove the lever.
2. Unscrew stem retention nut and lift out stem
assembly.
3. Install the stem assembly and retighten the stem
retention nut.
4. Replace cover and reinstall trigger lever. Use the
new lock nut provided (Fig. E).
Option B: Replace the trigger valve assembly
A replacement trigger valve assembly (part no. 13-
01690) is available from your Sapphire distributor.
1. Remove the four cover screws (Fig. B) and lift off the
cover.
2. Depress the hose release ring on the solution outlet
tube and pull out the tube. Avoid kinking the tube.
Orifice
(03-01903)
Nylon washer
(03-01652)
2
Trigger lever
nut and bolt
Glide
Rear quick-
connect coupling
Hex nut. Loosen here
to access strainer.
Inline strainer
(03-01649)