Note: The laser beam is less visible at longer line lengths. It may be neces-
!
sary to use the laser detector to accurately locate the beam.
Plumb alignment
with a range of ±2.0° around the center of rotation. The default position is the mid-
point of the 4° adjustment range. The base unit emits a constant beep if the
adjustment limit is reached.
The level
and plumb
through a 360° range in the level or plumb plane. Pressing and holding the button
increases the speed of travel.

Out of Level

Out-of-level indicators alert you if the base unit is not on a level surface or if it is
out of self-leveling range. When the unit is out of level, the following occurs:
The base unit LED flashes red once per second.
The laser beam stops rotating (if in Spin mode) or dithering (if in Line
Dither/Scan mode) and flashes a laser dot in sync with the base unit LED.
The base unit beeper sounds in sync with the laser beam and base unit LED.
Note: If the laser beam is not turned on, an out-of-level condition is indicated
!
by flashes and beeps emitted from the base unit.
Reposition the unit to ensure that it is within the self-leveling range of ±6°. Once
the unit is within self-leveling range, the LED turns green and the laser beam stops
flashing. The RT-7690 series base unit resumes the mode of the last signal received.
Note: The out-of-level indicator overrides all other indicators. If the laser sys-
!
tem is in Low Battery or Power Standby mode and the laser system
becomes out of level, the out-of-level indicator overrides the Low Battery or
Power Standby mode indicator.

Laser Detector

The laser detector allows accurate laser beam detection outdoors, or under other
conditions when the laser beam is difficult to see. The following diagram illustrates
the laser detector LCD display icons.
To use the laser detector:
1.
Activate the RF remote control/laser detector with its keypad Power On/Off
button
. The unit emits a single beep, and icons in the lower portion of the
LCD display appear, showing all available options. This confirms that the unit
is activated, but the lasers and laser detector have not been turned on. It is
now safe to turn on the lasers and the laser detector.
Y
X
is available for the plumb laser in Line Dither/Scan mode,
Position buttons are used to move the line dither
Detector LCD Display
X
Y
Beeper On/Off
Detector Laser
Beam Locator
Low Battery
Indicator
Fine Resolution
Coarse Resolution
Level Spin Mode/
Speed Select
Level Line
Dither/Scan Mode
Plumb Spin Mode/
Speed Select
Plumb Line
Dither/Scan Mode
RF remote control/laser detector activated