DIM
50%
c. When the desired dim level is observed, release the button. This dim
level will then be set each time the lighting device is turned on.
Note: The Plug has an overload protection feature. Upon detecting an
overload condition, it will automatically switch off the load, disable the
On/Off/Dim button and the LED will flash rapidly for 30 seconds as warning.
When this happens, disconnect the load and check the load for symptoms of
failure. The overload protection of the Plug can be reset by simply unplugging
the Plug and re-connecting it to the electrical outlet.

Safety Precautions

1. Do not put the unit in humid or dusty places or facing direct sunlight.
2. The suitable ambient temperature for the unit is 0°C to 40°C.
3. Do not place the unit near combustible substances or any source of heat,
e.g. fire, radiators, boilers, etc.
Troubleshooting
The troubleshooting table lists some possible causes and solutions. Please
contact your original retailer or nearest service center if the below solutions
cannot solve your problem.
Symptom
Cause of Failure
The Plug is not working and
1. The Plug is not
LED is off
connected properly
2. The Plug is out of order
The Plug's LED is working, but
Check if the switch of
cannot control the ON/OFF
incandescent lamp
BRIGHTNESS
100%
Recommendation
1. Check if electrical
wiring to the plug is
in order.
2. Do not open the
Plug and send it for
repair
Set the On/Off
switch of the
switch of the connected
incandescent lamp
1. The unit didn't complete
Manual operation of the Plug is
working, but the Gateway is not
2. Cannot communicate
The LED flashes rapidly for 30
seconds and the unit cannot be
controlled

Reset to Factory Settings

To reset AD128 back to factory default state:
1. Press and hold the On/Off/Dim button for 3 seconds until the LED starts
to flash then release the button.
2.
Within 30 seconds, press and hold the button for more than 6 seconds.
The LED will start to flash, implying the device is reset back to factory
mode.
LED Table
The table below describes the LED indication at various stages of Plug
operation.
LED indication
Stage
LED blinks
1.During 30 seconds
rapidly for 30
after plugged into
seconds
electrical outlet
(blinks every 1
second)
2. After entering Manual
Binding mode
LED blinks
1. More than 30 seconds
slowly for a
have passed after
long period.
plugging into electrical
(blinks every 2
outlet
3
connected to the Plug is
connected
set to OFF
incandescent lamp
to ON
1. Bind with Gateway
successfully the binding
again
operation.
2. Place the Gateway
with the gateway
closer to the Plug
HSC04..
Remove the load
and ensure the
Overload occurred.
connected load does
not exceed 520
Watts
Explanation
The Plug enters Binding
mode for 30 seconds to bind
with Gateway.
If binding is successful, the
LED will turn on for 1 second
then off.
If binding fails, the LED
flashes rapidly for 3 times at
the end of 30 seconds.
Binding with Gateway has
failed. The Plug is still in
factory reset status.