Grille installation
The grille has four clips witch attach to corresponding hangers on the unit. The grille should
be positioned using these first.
The grille is then fixed into positioning by four bolts which are accessed through the four
corner panels on the grille.
The four connection bolts are located inside the inlet panel of the grille.
N.B
-
During the installation please ensure that the air vane motor in the grille corresponds
to the position of the refrigerant pipe entry into the indoor unit.
Fresh air inlet and exit to adjoining room
A in the 18K model is 352 x 101 mm
A in the other models 351 x 141 mm
B in the 18K model is 341 x 101 mm
B in the other models 341 x 141 mm
A
B
Diameter 68mm
84